Laboratory supercritical fluid extraction systems
Small scale supercritical co2 extraction machine, Laboratory SFE Systems, equipment, machine
Laboratory supercritical fluid extraction systems
Huaan can provide 0.5L-6L Laboratory Scale Supercritical Fluid Extraction Systems with different specifications for feasibility study, small sample preparation.
-
HA220-50-06 Supercritical co2 extraction equipment
Extraction kettle:Material: 0Cr18Ni9;
Volume: 1L,5L 2 set;
Maximum working pressure: 50MPa.
Separation tank:Material: 0Cr18Ni9;
Volume: 1L,2L 2sets;
Maximum working pressure: 30MPa.
-
HA220-50-05 Supercritical co2 extraction equipment
Extraction kettle:Material: 0Cr18Ni9;
Volume: 3L,2L 2 set;
Maximum working pressure: 50MPa.
Separation tank:Material: 0Cr18Ni9;
Volume: 1L,0.6L 2sets;
Maximum working pressure: 30MPa.
-
HA123-30-03 Supercritical co2 fractionation equipment
Separation kettle:Material:0Cr18Ni9;
Volume: 1L/26MPa, 2 sets.
Notes:Equipped with water jacket circulating heating system, adjustable temperature;
Fractionation column:The maximum working pressure of the fractionation tower: 30MPa (design pressure 35MPa);
Volume: 800ml×4 sections.
Notes:Working temperature: room temperature ~ 80 ℃. Maximum CO2 flow: 0-50L/h adjustable.
-
HA120-50-1 Supercritical co2 extraction equipment
Extraction kettle:Material: 0Cr18Ni9;
Volume: 1L, 1 set;
Maximum working pressure: 50MPa.
Separation tank:Material: 0Cr18Ni9;
Volume: 0.6L 2sets;
Maximum working pressure: 30MPa.
-
HA120-50-0.5 Supercritical co2 extraction equipment
Extraction kettle:Material: 0Cr18Ni9;
Volume: 0.5L, 1 set;
Maximum working pressure: 50MPa.
Separation tank:Material: 0Cr18Ni9;
Volume: 0.3L 2sets;
Maximum working pressure: 30MPa.
Models:
Type | Specification | Pressure | Combined type |
---|---|---|---|
HA120-50-(0.1-0.5) | 0.1-0.5L | 32MPa-50Mpa | One extraction kettle-Two separation kettle |
HA120-50-01 | 1L | 50Mpa | One extraction kettle-Two separation kettle |
HA120-50-01 | 1L | 50Mpa | One extraction kettle-Two separation kettle |
HA121-50-01 | 1L | 50Mpa | One extraction kettle-Two separation kettle-One column |
HA120-50-02 | 2L | 50Mpa | One extraction kettle-Two separation kettle |
HA121-50-01 | 2L | 50Mpa | One extraction kettle-Two separation kettle-One column |
HA230-50-06 | 5L+1L | 40-50Mpa | Two extraction kettle-Three separation kettle |
HA231-50-06 | 5L+1L | 40-50Mpa | Two extraction kettle-Three separation kettle-One column |
We can configure the corresponding volume pressure tempe rature and the rectification column of the equipment according to the produc lion process of the customer.
Our technical team has developed a special technology and rectification process for CBD Oil extraction, capable of separating 40-50% wax and impurities in the extract. Improve efficiency and reduce subsequent processing equipment investment and labor costs.
More models please visit:More models
Description:
Huaan can provide 0.5L-6L Laboratory Scale Supercritical Systems ( Equipment pictures ) with different specifications for feasibility study, small sample preparation.
Rapid screening of supercritical fluid extraction process, high degree of automation, complete system configuration and wide design parameters. The data is reliable and can be used for colleges and universities, research institutes, food processing plants, pharmaceutical units, etc. to do supercritical small-scale scientific research experiments and large-scale production of various materials and various processes. It can also realize other super through the selection of different components. Critical fluid applications, including supercritical particle preparation and crystallization, supercritical fluid reactions, supercritical drying cleaning, mixing and micropackaging, etc.
Further reading:Supercritical CO2 Extraction Methods for Plant Essential Oils And Bioactive Substances
Features:
Flexible customization, combined capacity combination
Quick-open design of the extraction kettle for safer and more convenient operation
Parallel connection of a variety of different safety devices to maximize the protection of experimental operators, the system is safe and reliable;
Digital measurement and automatic control of internal temperature and pressure of the extraction kettle
Continuous supercritical extraction of solid raw materials (with excellent extraction)
Electric, pulseless high precision CO2 pump
High performance cyclone separator
Recirculation of supercritical fluid
Energy saving, environmental protection, low noise
The equipment pipelines are all connected by double sealing gaskets, which can be replaced and expanded at any time according to the needs of users;
The use of high quality valve lines makes it easy to clean, maintain, maintain and replace parts for laboratory testing.
A variety of separation methods are available: users can design and manufacture secondary and tertiary high-pressure separation and collection systems and membrane separation systems for users to choose.
At the same time, it can also design and manufacture rectification columns for users to separate and rectify liquid products.
Simple and intuitive software, friendly interface
Further reading:Learn about Huaan premium parts
Technical parameter:
Maximum operating pressure: pressure 50-80MPa
Maximum operating temperature: 85 ° C
Extraction capacity: 0.1, 0.5, 1, 2, 5, 6 liters
Separate collection system: up to three high-pressure separation and collection systems, freely customizable capacity
Optional rectification column
All parameters can be customized according to customers